Product Specification :
- Rated charge current: 40AMax. PV input power: 520W for 12V battery system, 1040W for 24V battery system
- Max. PV open circuit voltage: 100VDC ;Grounding : Common negative
- Lead-acid batteries: Sealed(default),Gel(AGM),Flooded,User; (AGM batterysetting same as GEL parameters)
- Lithium batteries: LiFePO4(4s/8s),Li(NiCoMn)O2(3s/6s/7s),User
- Tracking efficiency : ≥99.5% , Max. conversion efficiency :98%
- Working environment temperature : -25℃~+50℃(100% input and output)
- Temperature: -20°C -- +70°C/-4°F -- 158°F
- LCD backlight time : 60S (Default)
- Terminal: 6AWG(16mm2 )
- Recommended cable: 6AWG(16mm2)
Package List:
- 1 x 40A Tracer4210AN Solar Charging Controller
- 1xTemperature sensor gift(Model:RT-MF58R47K3.81A)
- 1 x User Manual(English)
Added Feature than Tracer-A
- Supporting lithium batteries
- Communication port protection
- Over temperature derating function
- Charging self-activation function
Steps: Connect solar system in this order: 1.battery--> 2. load--> 3.PV array,and disconnect solar system in the reverse order >3. >2. >1.
- Battery must be connected first ! Never connect soalr panel array to controller Without/Before connect battery.
- DONOT connect any inverter/wind/Alternator or Charger into the chargecontroller directly ! You should connect with battery and add fuse .
- Ifthere is a long distance between the PV array and controller or betweenthe controller and battery, larger size wires should be used to reducethe voltage drop and improve performance. (Recommended wire size is onlyfor reference.)
Electronic Protections :
- Battery Protection: Lithium Battery Low Temperature protection,Battery Over Discharge protection, Battery Over Voltage protection
- Load Protection: Load Overload protection, Load Short Circuit protection Controller Overheating protection, TVS High Voltage Transients protection
- PV Protection: PV Over Current/power Protection , PV Short Circuit protection , PV Reverse Polarity protection ,Night Reverse Charging proection
How to program for Lithium Battery?
- Via Remote Meter (Accessories needed: MT50)
- Via PC Software (Accessories needed RS485 cable :CC-USB-RS485-150U )
- Via Phone APP [ Android or IOS], (Accessories needed:eBOX-WIFI-01 or eBOX-BLE-01 )
EPEVER MPPT Solar Charge Controller 40A,12V/24V auto ,Max PV 100V ,Max input 520W/12V ,1040W/24V , Works for Lead-acid and Lithium Battery
-